RPG08G
RPG08G

Purpose and range of use

RPG08 series of sensors designed to measure the pressure in liquids and gases.

Output signal of sensors is temperature-compensated throughout the operating temperature range.

Various versions of sensors in this series are designed for use in general industrial purposes and for specialized tasks.

Technical information

Technical parameters

Parameter
 Value
 Comment
Pressure measuring range, MPa
0…0,16 ÷ 0…100

Overpressure limit, % of FS1
110 ÷ 500
Dep. on FS
Burst pressure, % FS2
125 ÷ 800
Dep. on FS
Unsealing pressure, MPa
8 ÷ 200
Dep. on FS
Output signal type
Analogue 0,5 ÷ 4,5 V
Analogue÷ 20 mA
Digital RS485

Operating temperature range, °C
-40 ÷ 85
-40
÷ 1253
-55
÷ 1503

Total error (with non-linearity and hysteresis), % FS
±0,054; ±0,14; ±0,15; ±0,25; ±0,5; ±1; ±1,5

Additional error band, % FS/10 °C
±0,054 ÷ ±0,1
Dep. on transducer type
Accuracy grade, % FS
0,0014 ÷ 0,1
Specify when ordering
Value update time, ms
0,22005 ÷ 2200
Specify when ordering
Mean time to failure (at least), H
105000

Mean life (at least), years
12

Weight, g
50 ÷ 114
Dep. on material and transducer type
Recalibration interval
2 years


1The pressure limit requiring no further transducer's calibration. Average recovery time after reboot – 1 min.

2The pressure limit which might require further transducer's recalibration.

3Only for analogue transducers.

4Only for digital transducers.

50,2…200 value range is for analogue transducers type.

Overall dimensions & fittings
Types of output signal