Parameter
|
Value
|
Comment
|
Pressure measuring range, MPa
|
0…0,16 ÷ 0…100
|
|
Overpressure limit, % of FS1
|
110 ÷ 500
|
Dep. on FS
|
Burst pressure, % FS2
|
125 ÷ 800
|
Dep. on FS
|
Unsealing pressure, MPa
|
8 ÷ 200
|
Dep. on FS |
Output signal type
|
Analogue 0,5 ÷ 4,5 V Analogue 4 ÷ 20 mA Digital RS485
|
|
Operating temperature range, °C
|
-40 ÷ 85 -40 ÷ 1253 -55 ÷ 1503
|
|
Total error (with non-linearity and hysteresis), % FS
|
±0,054; ±0,14; ±0,15; ±0,25; ±0,5; ±1; ±1,5
|
|
Additional error band, % FS/10 °C
|
±0,054 ÷ ±0,1
|
Dep. on transducer type
|
Accuracy grade, % FS
|
0,0014 ÷ 0,1
|
Specify when ordering
|
Value update time, ms
|
0,2…2005 ÷ 2…200
|
Specify when ordering |
Mean time to failure (at least), H
|
105000
|
|
Mean life (at least), years
|
12
|
|
Weight, g
|
50 ÷ 114
|
Dep. on material and transducer type
|
Recalibration interval
|
2 years
|
|
1The pressure limit requiring no further transducer's calibration. Average recovery time after reboot – 1 min.
2The pressure limit which might require further transducer's recalibration.
3Only for analogue transducers.
4Only for digital transducers.
50,2…200 value range is for analogue transducers type.
|
|